Ang kit na ito ay ginagamit para sa in vitro qualitative detection ng influenza A virus (IFV A), influenza B virus (IFVB) , respiratory syncytial virus (RSV), adenovirus (Adv), human metapneumovirus (hMPV), rhinovirus (Rhv), Parainfluenza virus (PIV) at Mycoplasma pneumoniae (MP) nucleopharyngeal na virus ng tao. mga sample ng pamunas.


Detalye ng Produkto

Mga Tag ng Produkto

Pangalan ng produkto

HWTS-RT184-Walong Uri ng Respiratory Viruses Nucleic Acid Detection Kit (Fluorescence PCR)

Epidemiology

Ang impeksyon sa respiratory tract ay ang pinakakaraniwang uri ng sakit ng tao, na maaaring mangyari sa anumang kasarian, edad at rehiyon, at isa sa pinakamahalagang sanhi ng morbidity at kamatayan sa mundo.[1]. Kasama sa mga klinikal na karaniwang respiratory pathogen ang influenza A virus (IFV A), influenza B virus (IFV B), respiratory syncytial virus, adenovirus, human metapneumovirus, rhinovirus, parainfluenza virus (I/II/III) at mycoplasma pneumoniae, atbp.[2,3]. Ang mga klinikal na sintomas at palatandaan na dulot ng impeksyon sa respiratory tract ay medyo magkatulad, ngunit ang impeksyon na dulot ng iba't ibang mga pathogen ay may iba't ibang paraan ng paggamot, nakakagamot na epekto at kurso ng sakit.[4,5]. Sa kasalukuyan, ang mga pangunahing pamamaraan ng pagtuklas ng laboratoryo ng mga respiratory pathogen ay kinabibilangan ng: virus isolation, antigen detection at nucleic acid detection. Tinutukoy at tinutukoy ng kit na ito ang mga partikular na viral nucleic acid sa mga indibidwal na may mga palatandaan at sintomas ng impeksyon sa paghinga, kasabay ng iba pang mga resulta ng klinikal at laboratoryo upang tumulong sa diagnosis ng respiratory viral infection.

Mga Teknikal na Parameter

Imbakan

2-8 ℃

Shelf-life 12 buwan
Uri ng Ispesimen Oropharyngeal swab; Nasopharyngeal swab
Ct IFV A, IFVB, RSV, Adv, hMPV, Rhv, PIV, MP Ct≤35
CV <5.0%
LoD 200 Kopya/mL
Pagtitiyak

Cross reactivity: Walang cross reactivity sa pagitan ng kit at Boca virus, Cytomegalovirus, Epstein-Barr virus, Herpes simplex virus, varicella zoster Virus, Mumps virus, Enterovirus, measles virus, human coronavirus, SARS Coronavirus, MERS Coronavirus, Rotavirus, Norovirus, Chlamydia pneumoniae, Streptoellacoccus pneumoniae, Streptococcus pneumoniae, Klebsiella Pneumospora, Haemophilus influenzae, Bacillus pertussis, Staphylococcus aureus, Mycobacterium tuberculosis, gonococcus, Candida albicans, Candida glabra, Aspergillus fumigatus, Cryptococcus neoformans, Streptococcus salivarius, Moraxella catarrh, Corynebaclicus DNA

Pagsusuri ng interference: Piliin ang mucin (60mg/mL), dugo ng tao (50%), benephrin (2mg/mL), hydroxymethazoline (2mg/mL) 2mg/mL), sodium chloride na may 5% preservative (20mg/mL), beclomethasone (20mg/mL), dexamethasone (20mg/mL), dexamethasone (20niag/mL) (2mg/mL), budesonide (1mg/mL), mometasone (2mg/mL), fluticasone (2mg/mL), histamine hydrochloride (5mg/mL), benzocaine (10%), menthol (10%), zanamivir (20mg/mL), peramivir (1mg/mL), mucinpiromL (20mg/mL), mucinpirocin (20mg/mL). oseltamivir (60ng/mL), ribavirin (10mg/L), Ang mga resulta ay nagpakita na ang mga nakakasagabal na sangkap sa itaas na concentra

Mga Naaangkop na Instrumento Naaangkop sa type I detection reagent: Applied Biosystems 7500 Real-Time PCR Systems, QuantStudio®5 Real-Time PCR System, SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.), LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, Hangzhou Bioer technology), MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray RealTime CFXR, Systema BioRadCFX96 CFX96) Opus 96 Real-Time PCR System.

Naaangkop sa type II detection reagent: EudemonTM AIO800 (HWTS-EQ007) ng Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Daloy ng Trabaho

Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (na maaaring gamitin sa Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), at Macro & Micro-Test Viral DNA/RNA Kit (maaaring gamitin ang HWTS-3017-8)TM AIO800 (HWTS-EQ007)) ng Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Ang na-extract na sample volume ay 200μL at ang inirerekomendang elution volume ay 150μL.