SARS-CoV-2/influenza A /influenza B

Maikling Paglalarawan:

Ang kit na ito ay angkop para sa in vitro qualitative detection ng SARS-CoV-2, influenza A at influenza B nucleic acid ng nasopharyngeal swab at oropharyngeal swab sample kung sino sa mga taong pinaghihinalaang impeksyon ng SARS-CoV-2, influenza A at influenza B. Maaari rin itong gamitin sa pinaghihinalaang pneumonia at mga pinaghihinalaang kaso ng cluster at para sa qualitative detection at pagtukoy ng SARS-CoV-2, influenza A at influenza B nucleic acid sa nasopharyngeal swab at oropharyngeal swab sample ng novel Coronavirus infection sa ibang mga pangyayari.


Detalye ng Produkto

Mga Tag ng Produkto

Pangalan ng Produkto

HWTS-RT148-SARS-CoV-2/influenza A /influenza B Nucleic Acid Combined Detection Kit (Fluorescence PCR)

Channel

Pangalan ng Channel PCR-Mix 1 PCR-Mix 2
Channel ng FAM ORF1ab gene IVA
VIC/HEX Channel Panloob na kontrol Panloob na kontrol
CY5 Channel N gene /
ROX Channel E gene IVB

Mga Teknikal na Parameter

Imbakan

-18℃

Shelf-life 12 buwan
Uri ng Ispesimen nasopharyngeal swab at oropharyngeal swabs
Target SARS-CoV-2 tatlong target ( Orf1ab, N at E genes )/influenza A /influenza B
Ct ≤38
CV ≤10.0%
LoD SARS-CoV-2:300 Copy/mL

influenza A virus:500 Copy/mL

influenza B virus:500 Copy/mL

Pagtitiyak a) Ipinakita ng mga resulta ng cross test na ang kit ay tugma sa human coronavirus SARSr- CoV, MERSr-CoV, HcoV-OC43, HcoV-229E, HcoV-HKU1, HCoV-NL63, respiratory syncytial virus A at B, parainfluenza virus 1, 2 at 3, rhinovirusA, B at C, adenovirus 1, 2, 3, 4, 5, 7 at 55, human metapneumovirus, enterovirus A, B, C at D, human cytoplasmic pulmonary virus, EB virus, tigdas virus Human cytomegalovirus, rotavirus, norovirus, mumps virus, varicella zoster virus, Mycoplasma pneumoniae, Chlamydia pneumoniae, Legionella, pertussis, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pneumoniae, Streptococcus pyogenes, Klebsiella pneumoniae, Mycobacterium tuberculosis, Aspergi no glacius, Candida glauces cross reaction sa pagitan ng Pneumocystis yersini at Cryptococcus neoformans.

b) Anti interference ability: piliin ang mucin (60mg/mL), 10% (V/V) dugo ng tao, diphenylephrine (2mg/mL), hydroxymethylzoline (2mg/mL), sodium chloride (containing preservative) (20mg/mL), beclomethasone (20mg/mL), dexamethasone (20mg/mL), flunisone (20μg/mL), triamcinolone acetonide (2mg/mL), budesonide (2mg/mL), mometasone (2mg/mL), fluticasone (2mg/mL), histamine hydrochloride (5mg/mL), α-Interferon (800IU/mL), zanamivir (20mg/mL), ribavirin (10mg/mL), oseltamivir (60ng/mL), pramivir (1mg/mL), lopinavir (500mg/mL). ), ritonavir (60mg/mL), mupirocin (20mg/mL), azithromycin (1mg/mL), ceprotene (40μg/mL) Meropenem (200mg/mL), levofloxacin (10μg/mL) at tobramycin (0.6mg/mL) .Ang mga resulta ay nagpakita na ang mga nakakasagabal na sangkap sa mga konsentrasyon sa itaas ay walang interference na tugon sa mga resulta ng pagtuklas ng mga pathogen.

Mga Naaangkop na Instrumento Applied Biosystems 7500 Real-Time PCR Systems

Applied Biosystems 7500 Fast Real-Time PCR Systems

SLAN ®-96P Real-Time na PCR System

QuantStudio™ 5 Real-Time PCR System

LightCycler®480 Real-Time na PCR system

LineGene 9600 Plus Real-Time PCR Detection System

MA-6000 Real-Time Quantitative Thermal Cycler

BioRad CFX96 Real-Time PCR System

BioRad CFX Opus 96 Real-Time PCR System

Kabuuang PCR Solution

daloy ng trabaho

  • Nakaraan:
  • Susunod: