SARS-CoV-2/influenza A /influenza B
Pangalan ng Produkto
HWTS-RT148-SARS-CoV-2/influenza A /influenza B Nucleic Acid Combined Detection Kit (Fluorescence PCR)
Channel
Pangalan ng Channel | PCR-Mix 1 | PCR-Mix 2 |
Channel ng FAM | ORF1ab gene | IVA |
VIC/HEX Channel | Panloob na kontrol | Panloob na kontrol |
CY5 Channel | N gene | / |
ROX Channel | E gene | IVB |
Mga Teknikal na Parameter
Imbakan | -18℃ |
Shelf-life | 12 buwan |
Uri ng Ispesimen | nasopharyngeal swab at oropharyngeal swabs |
Target | SARS-CoV-2 tatlong target ( Orf1ab, N at E genes )/influenza A /influenza B |
Ct | ≤38 |
CV | ≤10.0% |
LoD | SARS-CoV-2:300 Copy/mL influenza A virus:500 Copy/mL influenza B virus:500 Copy/mL |
Pagtitiyak | a) Ipinakita ng mga resulta ng cross test na ang kit ay tugma sa human coronavirus SARSr- CoV, MERSr-CoV, HcoV-OC43, HcoV-229E, HcoV-HKU1, HCoV-NL63, respiratory syncytial virus A at B, parainfluenza virus 1, 2 at 3, rhinovirusA, B at C, adenovirus 1, 2, 3, 4, 5, 7 at 55, human metapneumovirus, enterovirus A, B, C at D, human cytoplasmic pulmonary virus, EB virus, tigdas virus Human cytomegalovirus, rotavirus, norovirus, mumps virus, varicella zoster virus, Mycoplasma pneumoniae, Chlamydia pneumoniae, Legionella, pertussis, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pneumoniae, Streptococcus pyogenes, Klebsiella pneumoniae, Mycobacterium tuberculosis, Aspergi no glacius, Candida glauces cross reaction sa pagitan ng Pneumocystis yersini at Cryptococcus neoformans. b) Anti interference ability: piliin ang mucin (60mg/mL), 10% (V/V) dugo ng tao, diphenylephrine (2mg/mL), hydroxymethylzoline (2mg/mL), sodium chloride (containing preservative) (20mg/mL), beclomethasone (20mg/mL), dexamethasone (20mg/mL), flunisone (20μg/mL), triamcinolone acetonide (2mg/mL), budesonide (2mg/mL), mometasone (2mg/mL), fluticasone (2mg/mL), histamine hydrochloride (5mg/mL), α-Interferon (800IU/mL), zanamivir (20mg/mL), ribavirin (10mg/mL), oseltamivir (60ng/mL), pramivir (1mg/mL), lopinavir (500mg/mL). ), ritonavir (60mg/mL), mupirocin (20mg/mL), azithromycin (1mg/mL), ceprotene (40μg/mL) Meropenem (200mg/mL), levofloxacin (10μg/mL) at tobramycin (0.6mg/mL) .Ang mga resulta ay nagpakita na ang mga nakakasagabal na sangkap sa mga konsentrasyon sa itaas ay walang interference na tugon sa mga resulta ng pagtuklas ng mga pathogen. |
Mga Naaangkop na Instrumento | Applied Biosystems 7500 Real-Time PCR Systems Applied Biosystems 7500 Fast Real-Time PCR Systems SLAN ®-96P Real-Time na PCR System QuantStudio™ 5 Real-Time PCR System LightCycler®480 Real-Time na PCR system LineGene 9600 Plus Real-Time PCR Detection System MA-6000 Real-Time Quantitative Thermal Cycler BioRad CFX96 Real-Time PCR System BioRad CFX Opus 96 Real-Time PCR System |